Using the System
BLY1 Wireless Alarm System
In more detail...
g) Part Arm the alarm system while at home
Press “Part-Arm” button at the control unit or press “PARTIAL ARM” button at the remote
key, (optional accessory) close the door and leave the house within the exit delay time
(30 seconds at factory setting,) both PIR and magnetic contact are activated for protection
after the exit delay time elapsed. When omitted zones (zone 6 to zone 8 at factory setting)
are triggered, they will not activate the alarm. Part-arm can also be used when you are
sleeping upstairs at night and wish to protect the ground of your property provided the PIRs
of Zones 6-8 are installed upstairs.
When the system is part-armed. Zone 5 PIR is used to protect the area next to the control
panel with a delay period (30 seconds at factory setting).
h) Disarm the alarm system while entering the house
When you open the entrance door, the count down warning sound (entry delay time) will be
started. Enter your four-digit User PIN code at the control unit or press “DISARM” button
at the remote key (optional accessory) within the delay time (30 seconds at factory setting,)
system will return to standby mode. At any time, the user PIN code can be entered to set to
the standby mode.
1. Anti-Jamming detection feature
Press and hold the “Anti-Jam On/Off” button for over 10 seconds in standby mode to turn
anti-jamming function ON/OFF. The corresponding “Anti-Jam” green LED will turn ON/OFF.
Anti-Jam LED – Green colour (constantly on means enabled, Flashing means jamming
is detected)
Low battery detection
Control unit:
When the Control unit’s backup battery falls
below 7.2V to 7.6V for over one minute,
TAMPER LED will ash to show low battery
status.
PIR Detectors:
The PIR Detectors have a built in buzzer which
wills sound in the event of a low battery status.
Please replace the batteries within 2 weeks.
Magnetic Door/Window Contact Detectors:
The magnetic Door/Window contact detectors have a built in buzzer which wills sound in the
event of a low battery status. Please replace the batteries within 2 weeks.
When replacing any batteries, ensure you power OFF the control unit completely to prevent the
tamper function from triggering the alarm. After having replaced any batteries, reconnect the
Detector
Part Arm
mode
ARM mode Usage
Magnetic
Contact
Zone 1 Instant Delay
Exit/Entry
Zone
Zone 2 Instant Delay
Zone 3 Instant Delay
Zone 4 Instant Delay
PIR
Zone 5 Delay Delay
Protect area far
away from
Exit/Entry Zone
Zone 6 Disable Delay
Zone 7 Disable Delay
Zone 8 Disable Delay
Summary of the detector responses in different mode
NOTE: If a door/window where a magnetic contact detector is installed (zones 1-4) is
opened, the alarm will activate instantly.
9V Alkaline
battery
> One
minute
< 7.2V
~ 7.6V